Section / Paragraph |
Pleasure Craft |
Non-Pleasure Craft |
|||
|---|---|---|---|---|---|
| ≤ 6 m | > 6 m | ≤ 6 m | > 6 m | ||
|
0 |
INTRODUCTION |
|
|
|
|
|
0.1 |
Definitions |
X |
X |
X |
X |
|
0.2 |
Pleasure Craft of more than 24 metres |
|
X |
|
|
|
0.3 |
Standard Incorporated by Reference |
X |
X |
X |
X |
|
0.4 |
Particular Vessel Design |
X |
X |
X |
X |
|
0.5 |
Major Modifications |
X |
X |
X |
X |
|
0.6 |
Plans |
|
|
X |
X |
|
0.7 |
Safety Notices |
X |
X |
X |
X |
|
1 |
HULL SERIAL NUMBERS |
|
|
|
|
|
1.1 |
Scope |
X |
X |
X |
X |
|
1.2 |
Hull Serial Number (HIN) |
X |
X |
X |
X |
|
2 |
COMPLIANCE NOTICES |
|
|
|
|
|
2.1 |
Scope |
X |
X |
X |
X |
|
2.2 |
Compliance Notices |
X |
X |
X |
X |
|
2.2.1 |
General |
X |
X |
X |
X |
|
2.2.2 |
Vessels of not more than 6 metres in length – Capacity Label |
X |
|
X |
|
|
2.2.3 |
Vessels of more than 6 metres in length – Conformity Label |
|
X |
|
X |
|
3 |
CONSTRUCTION REQUIREMENTS |
|
|
|
|
|
3.1 |
Scope |
X |
X |
X |
X |
|
3.2 |
Structural Strength |
X |
X |
X |
X |
|
3.3 |
Watertight Integrity |
X |
X |
X |
X |
|
3.3.1 |
Fittings and Through-Hull Penetrations |
X |
X |
X |
X |
|
3.3.2 |
Windows, Portlights, Hatches, Deadlights and Doors |
X |
X |
X |
X |
|
3.3.3 |
Windows, Portlights, Hatches, Deadlights, and Doors of more than 6 metres |
|
|
|
X |
|
3.3.4 |
Drainage and Hull Penetrations |
X |
|
X |
X |
|
3.3.5 |
Motor Wells |
X |
X |
X |
X |
|
3.4 |
Personal Watercraft |
X |
X |
X |
X |
|
3.5 |
Protection from Falls |
X |
X |
X |
X |
|
3.5.1 |
Scope |
X |
X |
X |
X |
|
3.5.2 |
Non-Pleasure Craft of more than 6 metres |
|
|
|
X |
|
3.5.3 |
Pleasure Craft of All Sizes and Non-Pleasure Craft of 6 metres and less |
X |
X |
X |
|
|
3.6 |
Discharge of Sewage |
X |
X |
X |
X |
|
3.7 |
Navigation Lights |
X |
X |
X |
X |
|
4 |
HULL DESIGN REQUIREMENTS AND CALCULATION OF RECOMMENDED MAXIMUM CAPACITIES FOR VESSELS NOT MORE THAN 6 METRES IN LENGTH |
|
|
|
|
|
4.1 |
Scope |
X |
|
X |
|
|
4.2 |
Definitions |
X |
|
X |
|
|
4.3 |
Recommended Maximum Safety Limits for Monohull Vessels |
X |
|
X |
|
|
4.3.1 |
Recommended Gross Load Calculation (Intact Condition) |
X |
|
X |
|
|
4.3.2 |
Recommended Maximum Number of Persons Calculation |
X |
|
X |
|
|
4.3.3 |
Recommended Maximum Power Calculation |
X |
|
X |
|
|
4.4 |
Flotation Requirements for Monohull Vessels |
X |
|
X |
|
|
4.5 |
Recommended Maximum Safety Limits for Pontoon Vessels |
X |
|
X |
|
|
4.5.1 |
Calculation Criteria (Intact Condition) |
X |
|
X |
|
|
4.5.2 |
Stability Testing |
X |
|
X |
|
|
4.5.3 |
Recommended Maximum Gross Load Calculation |
X |
|
X |
|
|
4.5.4 |
The Recommended Maximum Number of Persons Calculation |
X |
|
X |
|
|
4.5.5 |
The Recommended Maximum Power Calculation |
X |
|
X |
|
|
4.6 |
Recommended Maximum Safety Limits for Inflatable and Rigid Hull Inflatable Vessels |
X |
|
X |
|
|
4.6.1 |
Calculation Criteria (Intact Condition) |
X |
|
X |
|
|
4.6.2 |
Recommended Maximum Gross Load Calculation |
X |
|
X |
|
|
4.6.3 |
Recommended Maximum Number of Persons Calculation |
X |
|
X |
|
|
4.6.4 |
The Recommended Maximum Power Calculation |
X |
|
X |
|
|
5 |
HULL DESIGN REQUIREMENTS FOR NON-PLEASURE CRAFT EXCEEDING 6 METRES |
|
|
|
|
|
5.1 |
Scope |
|
|
|
X |
|
5.2 |
Stability Standards for All Types of Vessels |
|
|
|
X |
|
5.3 |
Stability Standard for Monohull Vessel Other than Inflatable or Rigid Hull Inflatable |
|
|
|
X |
|
5.4 |
Stability Standard for Pontoon Vessels |
|
|
|
X |
|
6 |
VENTILATION SYSTEMS |
|
|
|
|
|
6.1 |
Scope |
X |
X |
X |
X |
|
6.2 |
General |
X |
X |
X |
X |
|
6.3 |
Ventilation of Spaces Containing Source of Gasoline Vapour |
X |
X |
X |
X |
|
6.4 |
Diesel Engine and Fuel Tank Space Ventilation |
X |
X |
X |
X |
|
6.5 |
Battery Spaces |
X |
X |
X |
X |
|
7 |
FUEL SYSTEMS |
|
|
|
|
|
7.1 |
Scope |
X |
X |
X |
X |
|
7.2 |
General |
X |
X |
X |
X |
|
7.3 |
Fuel Tanks |
X |
X |
X |
X |
|
7.4 |
Fuel Lines |
X |
X |
X |
X |
|
7.5 |
Fittings, Joints and Connections |
X |
X |
X |
X |
|
7.6 |
Fuel Line Valves |
X |
X |
X |
X |
|
7.7 |
Fuel Filters and Strainers |
X |
X |
X |
X |
|
7.8 |
Fuel Pumps |
X |
X |
X |
X |
|
7.9 |
Grounding |
X |
X |
X |
X |
|
7.10 |
Carburetors (Gasoline) |
X |
X |
X |
X |
|
7.11 |
Fuel System Labelling |
X |
X |
X |
X |
|
7.12 |
Outboard Motor Installations |
X |
X |
X |
X |
|
8 |
ELECTRICAL SYSTEMS |
|
|
|
|
|
8.1 |
Scope |
X |
X |
X |
X |
|
8.2 |
Alternative Standards |
X |
X |
X |
X |
|
8.3 |
General |
X |
X |
X |
X |
|
8.4 |
Ignition Protection |
X |
X |
X |
X |
|
8.5 |
Grounding |
X |
X |
X |
X |
|
8.6 |
Batteries |
X |
X |
X |
X |
|
8.7 |
Conductors |
X |
X |
X |
X |
|
8.8 |
Receptacles |
X |
X |
X |
X |
|
8.9 |
Overcurrent Protection |
X |
X |
X |
X |
|
8.10 |
Panelboards |
X |
X |
X |
X |
|
8.11 |
Emergency Lighting for Non-Pleasure Craft of more than 6 metres |
|
|
|
X |
|
8.12 |
Electrical Systems of 50 Volts or More |
X |
X |
X |
X |
|
9 |
MACHINERY SYSTEMS |
|
|
|
|
|
9.1 |
Exhaust Systems |
X |
X |
X |
X |
|
9.2 |
Main and Auxiliary Machinery |
|
|
|
X |
|
9.2.1 |
Scope |
|
|
|
X |
|
9.2.2 |
General |
|
|
|
X |
|
9.2.3 |
Engine Starting |
|
|
|
X |
|
9.2.4 |
Operating Position Instruments and Controls |
|
|
|
X |
|
9.2.5 |
Shafting and Propellers |
|
|
|
X |
|
9.2.6 |
Steering Systems |
|
|
|
X |
|
9.3 |
Bilge Pumping Arrangements |
|
|
|
X |
|
9.3.1 |
Scope |
|
|
|
X |
|
9.3.2 |
General |
|
|
|
X |
|
9.3.3 |
Bilge Pumping Systems |
|
|
|
X |
|
9.3.4 |
Automatic Bilge Alarm and Pump Running Indicator |
|
|
|
X |
|
9.4 |
Pressure Vessels |
X |
X |
X |
X |
|
10 |
FIRE SAFETY |
|
|
|
|
|
10.1 |
Scope |
|
|
X |
X |
|
10.2 |
Means of Escape |
|
|
|
X |
|
10.3 |
Fire Detection and Alarm |
|
|
X* |
X |
|
10.4 |
Fire Fighting |
|
|
X* |
X |
* See information note regarding elements that are not part of the Construction Requirements in Section 0.1.