8.1.1 This section applies to all small vessels that have gasoline or diesel engines for propulsion or electrical generating power or LPG (Liquefied Petroleum Gas) or CNG (Compressed Natural Gas) equipment on board.
8.2.1 The requirements of ABYC Standards for Small Craft E-11 AC and DC Electrical Systems on Boats and E-10 Storage Batteries may be met instead of the requirements of sections 8.3 to 8.13.
8.3.1 All switches and controls shall be marked to indicate their usage except where there is a switch or electrical control whose function is obvious and where the operation of the device could not, under normal operation, cause a hazardous condition.
8.3.2 Single-pole breakers shall be installed in the positive conductor.
8.3.3 Switches shall be rated for the voltage and the current rating of the connected load of the circuit.
8.3.4 Electrical equipment, such as ignition systems, motors, pumps, fans, and controllers, shall be marked or identified with the following:
8.3.5 Circuit Breakers shall:
8.3.6 Fuses shall be:
8.3.7 Every integral overcurrent protect device without manual reset is permitted for use provided the circuit is protected by a fuse or trip-free breaker.
8.3.8 All permanently installed electrical equipment and appliances shall be securely mounted to the ship's structure.
8.3.9 With the exception of engine mounted equipment, all DC appliances and fixed electrical equipment shall be designed so that all current carrying parts are insulated from exposed electrically conductive parts.
8.3.10 The following devices need not comply with paragraph 8.3.9 if one conductor is connected to the exposed electrically conductive parts, provided that the connected conductor is the negative conductor, the polarity of both the negative and positive connections are identified, the device is mounted only on a non-conductive surface, and the device is not bonded:
8.3.11 Every exposed conductive non-current part of electrical equipment that may normally be in contact with bilge or seawater shall be connected to a DC grounding system, except for small vessels not equipped with a DC grounding system, double insulated devices, and isolated metal parts in nonconductive material.
8.3.12 Grounded liquid level gauge transmitters mounted on metallic fuel tanks or tank plates shall have the transmitter negative return conductor connected directly to the engine negative terminal or its bus. This conductor shall serve as the tank bonding or static ground conductor. Where this conductor is employed as the bonding conductor, it shall be not less than 8 AWG, and no other device shall be connected to the conductor.
8.3.13 The negative terminal of the battery and the negative side of the DC distribution system shall be connected to the engine negative terminal or its bus. The negative return on vessels with outboard motors shall be connected to the battery negative terminal unless provisions have been specifically provided for the return to be connected to the motor negative terminal by the outboard manufacturer.
8.3.14 Where an accessory negative bus is used, the following requirements apply:
8.3.15 Where the DC distribution system is a two-wire system with supply and return, the engine block may be used as the common return for accessories mounted on the engine, except on metallic vessels where the engine is not isolated from the hull.
8.3.16 If a small vessel with a grounded DC system has a multiple engine installation with grounded cranking motors that includes an auxiliary generator engine(s), the engines shall be connected to each other by a common conductor that can carry the starting current of each of the grounded cranking motor circuits. Multiple outboard motors shall be connected at the negative battery terminal
8.3.17 WIf a small vessel is equipped with a crossover (parallel) cranking motor system in a multi engine installation, including auxiliary generator(s), the engine shall be connected with a cable large enough to carry the cranking motor circuit; this cable shall be in addition to and independent of any other electrical connections to the engines including those in subsection 8.3.16, except in the case of ungrounded DC systems or outboard motors.
8.3.18 If a paralleling switch is installed in crossover circuitry of 8.3.17, it shall be rated to carry the largest cranking motor current. The switch may be of a maintained type or solenoid operated.
8.4.1 Every electrical component shall be ignition protected in accordance with Society of Automotive Engineers Standard SAE J1171, External Ignition Protection of Marine Electrical Devices or Underwriters Laboratories UL 1500, Ignition Protection Test for Marine Products unless the component is isolated from the fuel source, such as engines, stoves, valves, connections, or other fittings on vent lines, fill lines, distribution lines, or fuel tanks.
8.4.1.1 Exceptions to 8.4.1 are the following:
any small vessel using diesel fuel as the only fuel source; and
electrical devices in accommodation spaces or open compartments, or both, having at least 97 cm2 of open area per cubic metre of net compartment volume exposed to the atmosphere outside of the small vessel.
8.4.1.2 Electrical devices in compartments containing LPG or CNG appliances, cylinders fittings, valves, or regulators shall be ignition protected (refer to paragraph 8.4.1.1 for exceptions).
8.4.2 Isolation of an electrical component from a fuel source shall be provided by:
8.4.3 A bulkhead, as detailed in paragraph 8.4.2 shall:
8.4.4 Fuel tank, fuel filter, or fuel line fittings shall not be installed over a source of ignition. All personal watercraft are exempt from this requirement.
8.5.1 Where a small vessel has more than one gasoline engine, the grounded cranking motor circuits shall meet the requirements of 8.3.16.
8.5.2 The engine block may be used as the common return for accessories mounted on the engine, except on metallic small vessels, where the engine is not isolated from the hull.
8.5.3 A metallic hull or the grounding conductor shall not be used as the return conductor.
8.5.3.1 If one side of the DC system is grounded, it shall be of negative polarity.
8.5.3.2 In steel and aluminum small vessels, non-conducting exposed metal parts of electrical equipment that requires grounding shall be effectively grounded to the hull.
8.5.4 On small wood, fiber-reinforced plastic and composite vessels, a continuous ground conductor shall be installed to facilitate the grounding of non-conducting exposed metal parts of electrical, electronic, and communication equipment that requires grounding. The ground conductor shall terminate at a point on the main engine or at a copper plate of area not less than 0.2 m2 fixed to the keel below the light waterline so as to be fully immersed under all conditions of heel or trim.
8.5.5 Every grounding conductor shall be of copper or other corrosion-resistant material and shall be securely installed and protected, where necessary, against damage and electrolytic corrosion.
8.5.6 Every grounding connection to the small vessel's structure, or on wood, fiber-reinforced plastic, and composite small vessels, to the continuous ground conductor, shall be made in an accessible position and shall be secured by a screw or connector of brass or other corrosion-resistant material used solely for that purpose.
8.6.1.1 Batteries shall be installed in a dry, ventilated location above bilge water level, accessible for inspection and maintenance.
8.6.1.2 Batteries shall not be tapped for voltages other than the total voltage of the cells comprising the battery.
8.6.1.3 Batteries, as installed in every small vessel, shall be capable of inclinations of up to 40 degrees without leakage of electrolyte. A means shall be provided for containment of any spilled electrolyte.
8.6.1.4 Batteries shall be protected against mechanical damage by either location or an enclosure, and electrically protected by a non-conductive cover to protect metal objects coming in direct contact with the ungrounded terminals of the battery.
8.6.1.5 Every battery shall be secured so as not move more than 25 mm (1 in) when a pulling force of twice the battery weight is applied through the centre of gravity in each of the following five directions for one minute:
8.6.1.6 Every metallic fuel line and fuel system component located within 305 mm (12 in) above the level of the top of an installed battery shall be shielded with dielectric material.
8.6.1.7 Means for adequate ventilation shall be provided to prevent the accumulation of hydrogen from the battery during charging or discharging cycles. Vented batteries shall not be installed in accommodation spaces.
8.6.1.8 The positive terminal of a battery shall be identified on the terminal or on the battery case near the terminal, with one of the following symbols:
8.6.1.9 No battery terminal connector shall depend upon spring tension for its connection to the terminal.
8.6.2 Battery Disconnect Switch
8.6.2.1 A battery disconnect switch shall be installed in the positive conductor from each battery or group of batteries, with a cold cranking average rating greater than 800 amperes, except for small vessels less than 8.0 m (26 ft 3 in) in length.
8.6.2.1.1 The following devices may be connected to the battery side of the battery switch described in paragraph 8.6.2.1; however, each device shall be provided with circuit protection in accordance with section 8.9:
8.6.2.2 Battery switches shall be placed in a readily accessible location as close as practicable to the battery, or batteries.
8.6.2.3 Battery disconnect switches shall be capable of carrying the maximum current of the distribution system including the intermittent load of the starter motor circuit.
8.6.2.4 Remote controlled battery disconnect switches, if used, shall also permit safe manual operation at the switch.
8.7.1General - Systems Less Than 50 Volts
8.7.1.1 This subsection does not apply to:
8.7.1.2 Every permanently installed cable and conductor shall:
8.7.1.3 For the purpose of 8.7.1.2(e), the types are those that are:
8.7.1.4 Conductors and flexible cords shall have the following surface markings:
| Types | Description | Available Insulation | Types of Conductors |
|---|---|---|---|
| TW | Moisture Resistant, Flame Tested Thermoplastic | 60°C | Single Conducturs |
| TWU | Heat and Moisture Resistant Flame Tested Thermoplastic | 60°C | Single Conductors |
| TWN | Heat and Moisture Resistant Flame Tested Thermoplastic | 75°C | Single Conductors |
| TW75 | Heat and Moisture Resistant Flame Tested Thermoplastic | 75°C | Single Conductors |
| TWU 75 | Heat and Moisture Resistant Flame Tested Thermoplastic | 75°C | Single Conductors |
| T90 Nylon | Heat and Moisture Resistant Flame Tested Thermoplastic | 90°C | Single Conductors or Multi-Conductors |
| RW 90 | Heat and Moisture Resistant Thermoset | 90°C | Multi Conductors |
8.7.1.5 Where flexible cords or power cables are used for portable equipment, they shall be of a type SO, ST, SJO, SJT, SJOW, or SJTW, as listed in the CSA Canadian Electrical Code, Part 1, or be of a similar cable that has been constructed to a recognized national standard.
8.7.1.6 Except for intermittent surges, no conductor shall carry a current greater than that specified in Table 8-2 for the conductor's gauge and temperature rating.
8.7.1.7 In circuits where voltage drop must be kept to a minimum, the following maximum voltage drops are permitted:
(For the calculation of the above voltage drops, refer to Tables 8-3 and 8-4)
8.7.1.8 Conductors shall be not less than 16 AWG (1 mm), other than those conductors contained in manufacturer's equipment and communication circuits of less than 1 amp.
8.7.2.1 The colour coding shown in Table 8-5 identifies colours for DC general wiring purposes on vessels together with one selection of colours used for engine accessories. Other means of cable identification may be employed provided a wiring diagram of the electrical system indicating the method of identification is provided particular to the vessel electrical installation.
|
Conductor Size (Circular Mils) |
Temperature rating of conductor insulation | ||||||||
|---|---|---|---|---|---|---|---|---|---|
| (AWG) | 60° C | 75° C | 80° C | 90° C | 105° C | 125° C | 200° C | ||
| 1 620 | 18 | 10 | 10 | 15 | 20 | 20 | 25 | 25 | |
| 2 580 | 16 | 15 | 15 | 20 | 25 | 25 | 30 | 35 | |
| 4 110 | 14 | 20 | 20 | 25 | 30 | 35 | 40 | 45 | |
| 6 530 | 12 | 25 | 25 | 35 | 40 | 45 | 50 | 55 | |
| 10 400 | 10 | 40 | 40 | 50 | 55 | 60 | 70 | 70 | |
| 16 500 | 8 | 55 | 65 | 70 | 70 | 80 | 90 | 100 | |
| 26 300 | 6 | 80 | 95 | 100 | 100 | 120 | 125 | 135 | |
| 41 700 | 4 | 105 | 125 | 130 | 135 | 160 | 170 | 180 | |
| 52 600 | 3 | 120 | 145 | 140 | 155 | 180 | 195 | 210 | |
| 66 400 | 2 | 140 | 170 | 175 | 180 | 210 | 225 | 240 | |
| 83 700 | 1 | 165 | 195 | 210 | 210 | 245 | 265 | 280 | |
| 106 000 | 0 | 195 | 230 | 245 | 245 | 285 | 305 | 325 | |
| 133 000 | 00 (2/0) | 225 | 265 | 285 | 285 | 330 | 355 | 370 | |
| 168 000 | 000 (3/0) | 260 | 310 | 330 | 330 | 385 | 410 | 430 | |
| 212 000 | 0000 (4/0) | 300 | 360 | 385 | 385 | 445 | 475 | 510 | |
CORRECTION FACTORS
| Temperature Rating | 60°C | 75°C | 80°C | 90°C | 105°C | 125°C | 200°C |
|---|---|---|---|---|---|---|---|
| Correction Factor | 0.58 | 0.75 | 0.78 | 0.82 | 0.85 | 0.89 | 1.00 |
| Number of current carrying conductors | Correction Factor |
|---|---|
| 3 | 0.70 |
| 4 to 6 | 0.60 |
| 7 to 24 | 0.50 |
| 25 or more | 0.40 |
8.7.2.2 If coloured tape is employed for colour coding, it shall be not less than 5 mm (3/16 in) wide and shall make at least two (2) complete turns around the conductor in a visible location adjacent to the terminal.
8.7.3 Secondary Circuits of Ignition Systems
8.7.3.1 Every conductor in a secondary circuit of an ignition system shall conform to Society of Automotive Engineers Standard SAE Standard J2031.
8.7.3.2 The connection of every ignition conductor to a spark plug, coil, or distributor shall have a tight fitting cap, boot, or nipple.
8.7.4 Conductors - Support and Protection
8.7.4.1 This subsection does not apply to communication systems, electronic navigation equipment, or highvoltage secondary conductors and termination in ignition systems.
8.7.4.2 Except for the first 1000 mm (3 ft 3 in) of a conductor leading from a battery terminal, every conductor or group of conductors shall be supported by clamps or straps at intervals not greater than 500 mm (1 ft 8 in) unless the conductor or group of conductors is enclosed in a rigid duct or conduit.
8.7.4.3 Non-metallic straps or clamps shall be resistant to oil, gasoline, and water, and shall not break under flexing at a temperature range of - 34°C to 121°C and where exposed to sunlight shall not be sensitive to ultraviolet radiation.
8.7.4.4 Where metal clamps are lined with an insulating material, the material shall be resistant to oil, gasoline, and water, and be compatible with the insulation or sheath.
8.7.4.5 Clamps, straps, ducts, or conduits shall be designed to prevent chafing or damage to the conductor insulation.
8.7.4.6 Provision shall be made to prevent stress being placed on any conductor that connects two components that can move in relation to each other.
8.7.4.7 Every conductor or group of conductors that passes through a bulkhead, structural member, junction box, or other rigid surface shall be protected from abrasion.
8.7.4.8 Every conductor shall be protected from damage due to exposure to heat sources capable of damaging the insulation.
8.7.4.9 Current carrying conductors shall be routed as high as practicable above the bilge water level and other areas where water may accumulate. If conductors must be routed in the bilge or other areas where water may accumulate, the wiring and connections shall be watertight.
8.7.4.10 AC and DC conductors or multiconductors shall be separately sheathed in conduit or cable or trunking or bundled, or otherwise kept separate from each other.
TABLES 8.3. Conductor sizes for 3% Drop in Voltage
Length of conductor from Source of Current to Device and Back to Source - Feet
| Total Amps* | Metres - Feet | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3 m - 10 ft |
4.5 m - 15 ft |
6 m - 20 ft |
8 m - 25 ft |
9 m - 30 ft |
12 m - 40 ft |
15 m - 50 ft |
18 m - 60 ft |
20 m - 70 ft |
25 m - 80 ft |
27 m - 90 ft |
30 m - 100 ft |
33 m - 110 ft |
36 m - 120 ft |
40 m - 130 ft |
43 m - 140 ft |
45 m - 150 ft |
48 m - 160 ft |
52 m - 170 ft |
|
| 3 | 18 | 16 | 14 | 12 | 12 | 10 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
| 10 | 14 | 12 | 10 | 10 | 10 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 |
| 15 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | 2 | 2 | 2 | 2 | 2 | 2 | 1 | 1 | 1 | 1 |
| 20 | 10 | 10 | 8 | 6 | 6 | 6 | 4 | 4 | 2 | 2 | 2 | 2 | 1 | 1 | 1 | 0 | 0 | 0 | 2/0 |
| 25 | 10 | 8 | 6 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 | 2/0 | 3/0 |
| 30 | 10 | 8 | 6 | 4 | 4 | 4 | 2 | 2 | 1 | 0 | 0 | 0 | 0 | 2/0 | 2/0 | 3/0 | 3/0 | 3/0 | 3/0 |
| 40 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 0 | 2/0 | 2/0 | 2/0 | 2/0 | 3/0 | 3/0 | 4/0 | 4/0 | 4/0 | 4/0 |
| 50 | 6 | 6 | 4 | 2 | 2 | 2 | 1 | 0 | 2/0 | 3/0 | 3/0 | 3/0 | 3/0 | 4/0 | 4/0 | - | - | - | - |
| 60 | 6 | 4 | 4 | 2 | 2 | 1 | 0 | 2/0 | 3/0 | 4/0 | 4/0 | 4/0 | 4/0 | - | - | - | - | - | - |
| 70 | 6 | 4 | 2 | 1 | 1 | 0 | 2/0 | 3/0 | 3/0 | 4/0 | 4/0 | - | - | - | - | - | - | - | - |
| 80 | 6 | 4 | 2 | 1 | 0 | 0 | 3/0 | 3/0 | 4/0 | - | - | - | - | - | - | - | - | - | - |
| 90 | 4 | 2 | 2 | 0 | 2/0 | 2/0 | 3/0 | 4/0 | 4/0 | - | - | - | - | - | - | - | - | - | - |
| 100 | 4 | 2 | 2 | 0 | 2/0 | 2/0 | 3/0 | 4/0 | - | - | - | - | - | - | - | - | - | - | - |
| Total Amps* | Metres - Feet | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3 m - 10 ft |
4.5 m - 15 ft |
6 m - 20 ft |
8 m - 25 ft |
9 m - 30 ft |
12 m - 40 ft |
15 m - 50 ft |
18 m - 60 ft |
20 m - 70 ft |
25 m - 80 ft |
27 m - 90 ft |
30 m - 100 ft |
33 m - 110 ft |
36 m - 120 ft |
40 m - 130 ft |
43 m - 140 ft |
45 m - 150 ft |
48 m - 160 ft |
52 m - 170 ft |
|
| 5 | 18 | 18 | 18 | 16 | 16 | 14 | 12 | 12 | 12 | 10 | 10 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 |
| 10 | 18 | 16 | 14 | 12 | 12 | 10 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 6 |
| 15 | 16 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 4 | 2 |
| 20 | 14 | 12 | 10 | 10 | 10 | 8 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 |
| 25 | 12 | 12 | 10 | 10 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 2 | 1 |
| 30 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 1 | 1 | 1 | 1 |
| 40 | 10 | 10 | 8 | 6 | 6 | 6 | 4 | 4 | 2 | 2 | 2 | 2 | 1 | 1 | 1 | 0 | 0 | 0 | 2/0 |
| 50 | 10 | 8 | 6 | 6 | 6 | 4 | 4 | 2 | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 | 2/0 | 3/0 |
| 60 | 10 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 | 3/0 | 3/0 | 3/0 | 4/0 |
| 70 | 8 | 6 | 6 | 4 | 4 | 0 | 2 | 1 | 1 | 0 | 0 | 2/0 | 2/0 | 3/0 | 3/0 | 3/0 | 3/0 | 4/0 | 4/0 |
| 80 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 0 | 0 | 2/0 | 2/0 | 3/0 | 3/0 | 3/0 | 4/0 | 4/0 | 4/0 | - |
| 90 | 8 | 6 | 4 | 4 | 2 | 2 | 1 | 0 | 0 | 2/0 | 2/0 | 3/0 | 3/0 | 4/0 | 4/0 | 4/0 | 4/0 | 4/0 | - |
| 100 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 0 | 2/0 | 2/0 | 3/0 | 3/0 | 4/0 | 4/0 | 4/0 | - | - | - | - |
| Total Amps* | Metres - Feet | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3 m - 10 ft |
4.5 m - 15 ft |
6 m - 20 ft |
8 m - 25 ft |
9 m - 30 ft |
12 m - 40 ft |
15 m - 50 ft |
18 m - 60 ft |
20 m - 70 ft |
25 m - 80 ft |
27 m - 90 ft |
30 m - 100 ft |
33 m - 110 ft |
36 m - 120 ft |
40 m - 130 ft |
43 m - 140 ft |
45 m - 150 ft |
48 m - 160 ft |
52 m - 170 ft |
|
| 3 | 18 | 18 | 18 | 18 | 16 | 16 | 14 | 14 | 12 | 12 | 12 | 12 | 10 | 10 | 10 | 10 | 10 | 10 | 8 |
| 10 | 18 | 16 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 6 | 6 | 6 | 6 |
| 15 | 16 | 16 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 4 | 4 |
| 20 | 16 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 4 | 2 |
| 25 | 14 | 14 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 |
| 30 | 14 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 1 | 1 | 1 |
| 40 | 12 | 12 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 1 | 1 | 1 | 1 |
| 50 | 12 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 0 |
| 60 | 10 | 10 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 | 2/0 |
| 70 | 10 | 10 | 6 | 6 | 6 | 4 | 2 | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 | 2/0 | 3/0 | 3/0 |
| 80 | 10 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 | 3/0 | 3/0 | 3/0 | 3/0 |
| 90 | 8 | 8 | 6 | 6 | 4 | 2 | 2 | 2 | 1 | 0 | 0 | 2/0 | 2/0 | 2/0 | 3/0 | 3/0 | 3/0 | 4/0 | 4/0 |
| 100 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 0 | 0 | 2/0 | 2/0 | 2/0 | 3/0 | 3/0 | 3/0 | 4/0 | 4/0 | 4/0 |
* Total current on circuit in amperage
TABLES 8.4. Conductor sizes for 10% Drop in Voltage
Length of Conductor from Source of Current to Device and Back to Source - Feet
| Total Amps* | Metres - Feet | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3 m - 10 ft |
4.5 m - 15 ft |
6 m - 20 ft |
8 m - 25 ft |
9 m - 30 ft |
12 m - 40 ft |
15 m - 50 ft |
18 m - 60 ft |
20 m - 70 ft |
25 m - 80 ft |
27 m - 90 ft |
30 m - 100 ft |
33 m - 110 ft |
36 m - 120 ft |
40 m - 130 ft |
43 m - 140 ft |
45 m - 150 ft |
48 m - 160 ft |
52 m - 170 ft |
|
| 5 | 18 | 18 | 18 | 18 | 18 | 16 | 16 | 14 | 14 | 14 | 12 | 12 | 12 | 12 | 12 | 10 | 10 | 10 | 10 |
| 10 | 18 | 18 | 16 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | 6 |
| 15 | 18 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 |
| 20 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 | 4 | 4 | 4 |
| 25 | 16 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 4 | 2 |
| 30 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 |
| 40 | 14 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| 50 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 1 | 1 | 1 | 1 |
| 60 | 12 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 1 | 1 | 1 | 0 | 0 | 0 |
| 70 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | 2 | 2 | 2 | 2 | 1 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 |
| 80 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 | 2/0 | 2/0 |
| 90 | 10 | 8 | 6 | 6 | 6 | 4 | 2 | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 | 2/0 | 3/0 | 3/0 |
| 100 | 10 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 1 | 0 | 0 | 0 | 2/0 | 2/0 | 2/0 | 3/0 | 3/0 | 3/0 |
| Total Amps* | Metres - Feet | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3 m - 10 ft |
4.5 m - 15 ft |
6 m - 20 ft |
8 m - 25 ft |
9 m - 30 ft |
12 m - 40 ft |
15 m - 50 ft |
18 m - 60 ft |
20 m - 70 ft |
25 m - 80 ft |
27 m - 90 ft |
30 m - 100 ft |
33 m - 110 ft |
36 m - 120 ft |
40 m - 130 ft |
43 m - 140 ft |
45 m - 150 ft |
48 m - 160 ft |
52 m - 170 ft |
|
| 5 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 16 | 16 | 16 | 16 | 14 | 14 | 14 | 14 | 14 | 14 | 12 |
| 10 | 18 | 18 | 18 | 18 | 18 | 16 | 16 | 14 | 14 | 14 | 12 | 12 | 12 | 12 | 12 | 10 | 10 | 10 | 10 |
| 15 | 18 | 18 | 18 | 16 | 16 | 14 | 14 | 12 | 12 | 12 | 10 | 10 | 10 | 10 | 10 | 8 | 8 | 8 | 8 |
| 20 | 18 | 18 | 16 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 | 6 |
| 25 | 18 | 16 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 6 | 6 | 6 | 6 |
| 30 | 18 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 |
| 40 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 | 4 | 4 | 4 |
| 50 | 16 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 4 | 2 |
| 60 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 |
| 70 | 14 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 2 |
| 80 | 14 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 2 | 2 |
| 90 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 2 | 1 | 1 |
| 100 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 1 | 1 | 1 | 1 |
| Total Amps* | Metres - Feet | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3 m - 10 ft |
4.5 m - 15 ft |
6 m - 20 ft |
8 m - 25 ft |
9 m - 30 ft |
12 m - 40 ft |
15 m - 50 ft |
18 m - 60 ft |
20 m - 70 ft |
25 m - 80 ft |
27 m - 90 ft |
30 m - 100 ft |
33 m - 110 ft |
36 m - 120 ft |
40 m - 130 ft |
43 m - 140 ft |
45 m - 150 ft |
48 m - 160 ft |
52 m - 170 ft |
|
| 5 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 18 | 16 | 16 | 16 | 16 | 14 | 14 | 14 | 14 |
| 10 | 18 | 18 | 18 | 18 | 18 | 18 | 16 | 16 | 14 | 14 | 14 | 14 | 12 | 12 | 12 | 12 | 12 | 12 | 12 |
| 15 | 18 | 18 | 18 | 18 | 18 | 16 | 14 | 14 | 14 | 12 | 12 | 12 | 12 | 10 | 10 | 10 | 10 | 10 | 10 |
| 20 | 18 | 18 | 18 | 16 | 16 | 14 | 14 | 12 | 12 | 12 | 10 | 10 | 10 | 10 | 10 | 8 | 8 | 8 | 8 |
| 25 | 18 | 18 | 16 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 8 |
| 30 | 18 | 18 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 6 | 6 | 6 |
| 40 | 18 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 |
| 50 | 16 | 14 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 | 6 | 4 | 4 |
| 60 | 16 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 |
| 70 | 14 | 14 | 12 | 10 | 10 | 8 | 8 | 8 | 6 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 |
| 80 | 14 | 12 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 |
| 90 | 14 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 2 |
| 100 | 14 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 6 | 4 | 4 | 4 | 4 | 2 | 2 | 2 | 2 | 2 | 2 |
* Total current on circuit in amperage
TABLE 8-5. General Wiring Colour Code
| Colour | Use | |
|---|---|---|
| Green or green w/ yellow stripe(s) | DC Grounding Conductors | |
| Black or Yellow | DC Negative Conductors | |
| Red | DC Positive Conductors | |
| Colour | Item | Use |
|---|---|---|
| Yellow w/ red strip (YR) | Starting circuit | Starting switch to solenoid |
| Brown/yellow stripe (BY) or Yellow (Y) - see note | Bilge blowers | Fuse or switch to blowers |
| Dark Gray (Gy) | Navigation lights | Fuse or switch to lights |
| Tachometer | Tachometer sender to gauge | |
| Brown (Br) | Generator armature | Generator armature to regulator |
| Alternator charge light | Generator | |
| Terminal/Alternator | ||
| Auxiliary terminal to light to regulator | ||
| Pumps | Fuse or switch to pumps | |
| Orange (O) | Accessory feed | Ammeter to alternator or generator output and accessory fuses or switches |
| Distribution panel to accessory switch | ||
| Purple (Pu) | Ignition | Ignition switch to coil and electrical instruments |
| Instrument feed | Distribution panel to electric instruments | |
| Dark blue | Cabin and instrument lights | Fuse or switch to lights |
| Light blue (Lt Bl) | Oil pressure | Oil pressure sender to gauge |
| Tan | Water temperature | Water temperature sender to gauge |
| Pink (Pk) | Fuel gauge | Fuel gauge sender to gauge |
| Green/stripe (G/x) | Tilt down and/or trim in | Tilt and/or trim circuits |
| Except G/Y | ||
| Blue/stripe (Bl/x) | Tilt up and/or trim out | Tilt and/or trim circuits |
Note on Table 8-5
1. If yellow is used for DC negative, the bilge blower must be brown with yellow stripe.
8.7.4.11 Each conductor that is part of the electrical system, except for conductors integral with engines as supplied by their manufacturers, shall be clearly differentiated between AC and DC and identified as to its function in the system.
8.7.4.12 DC equipotential bonding conductors shall be identified by green or green with yellow stripe insulation, which shall not be used to indicate current carrying conductors, or may be uninsulated.
8.7.4.13 In situations where boxes must be located in wet locations, space surrounding the boxes or enclosures of at least 6 mm (1/4 in) shall be provided to prevent the accumulation of water.
8.7.5 Conductors - Termination
8.7.5.1 This subsection does not apply to communications systems and electronic navigation equipment.
8.7.5.2 Every connection to a screw terminal or stud that is outside a junction box or enclosure shall be connected by a closed-ring connector, eyelet connector, captive spade connector, mechanical locking connector, or spring locking connector.
8.7.5.3 Every stripped connector that is connected to a compression screw terminal that is outside a junction box or other enclosure shall be mechanically secured to avoid stress on the connection.
8.7.5.4 Every single friction connection, spring type connector, and multi-connector plug that is outside a junction box or enclosure shall be capable of withstanding a force of 27 N for one minute, applied along the axial direction of the conductor.
8.7.5.5 Subject to paragraph 8.7.5.6, a soldered connection that is outside a junction box or enclosure shall not be the sole means of connection between two or more conductors, or between a conductor and connector. If the connection is soldered, the connection shall be located or supported to limit the flexing of the conductor where the solder has changed the stranded flexible conductor to a solid conductor.
8.7.5.6 A conductor may be soldered to a connector that joins the conductor to a battery terminal or stud, provided that the length of the soldered joint is at least 1.5 times the diameter of the stranded portion of the battery conductor.
8.7.5.7 Every ungrounded terminal or stud that is continuously energized:
8.7.5.8 Every termination that is composed of an ungrounded current carrying conductor, terminal fitting, and connector shall be protected from accidental short-circuiting with:
8.7.5.9 No conductor shall be joined to another conductor by a twist-on wire nut, or wire screw.
8.7.5.10 Blade type friction connectors may be used provided:
8.7.5.11 Terminal connectors of the ring or captive spade types shall be the same nominal size as the stud.
8.7.5.12 All connections shall be in locations protected from the weather or in weather tight enclosures.
8.7.5.12.1 Connections exposed to immersion shall be in watertight enclosures.
8.7.5.13 Metals used for terminal studs, nuts, or washers shall be corrosion resistant and galvanically compatible with the conductor and terminal. Aluminum and unplated steel shall not be used for studs, nuts, or washers in electrical circuits.
8.7.5.14 Mechanical and electrical joints shall be designed and installed to avoid damage to the conductors.
8.7.5.15 Setscrew connectors may be used provided the setscrew does not bear directly on the conductor strands.
8.7.5.16 Connectors of the crimp-on type shall be attached only by tools designed for the connector being used.
8.7.5.17 There shall not be more than four conductors connected to any one-stud terminal.
8.7.5.18 Where a conductor terminates at a switchboard, in a fixture, or in a junction box, a length of the conductor shall remain to provide strain relief at the terminal and allow for any future repairs.
8.7.5.19 Shanks of terminals shall be protected against accidental shorting except those employed for grounding lugs.
8.7.5.20 Harness-type wiring using multi-wire plugs and receptacles shall have cable clamps, molded connectors, insulation grips, or extended terminals to limit flexing at the connection point; the connectors where exposed to weather shall be weatherproof or watertight; each terminal shall be protected from accidental short-circuiting and the capacity shall meet or exceed the ampacity and temperature rating of the connecting conductors.
8.8.1 Receptacles and matching plugs used on DC systems shall not be interchangeable with those used on AC systems on the small vessel.
8.8.2 Receptacles installed in locations subject to rain, spray, or splash shall be protected by a cover with an effective weatherproof seal.
8.8.3 Receptacles, including connecting plugs, installed in areas subject to flooding or immersion shall be protected by an effective cover with a watertight seal.
8.9.1.1 This section does not apply to resistance conductors that control circuit amperage, conductors in secondary circuits of ignition systems, pigtails of less than 200 mm (8 in) of exposed length, and power supply conductors in cranking motor circuits.
8.9.1.2 Every ungrounded, current carrying conductor shall be protected by a manually reset, trip-free circuit breaker or fuse that shall be:
8.9.1.2.1 Overcurrent protection for each ungrounded conductor of a branch circuit shall be at the point of connection to panelboard or switchboard.
8.9.1.3 Except as provided in paragraph 8.9.1.4, the current rating of each circuit breaker or fuse shall not exceed the current rating of the smallest conductor in the circuit.
8.9.1.4 If the value specified in paragraph 8.9.1.3 does not correspond to a standard circuit breaker or fuse rating, the next larger rated circuit breaker or fuse may be used, provided it does not exceed 150% of the allowed current capacity of the conductor.
8.9.1.5 The voltage rating of each circuit breaker or fuse shall not be less than the nominal voltage of the circuit that it protects.
8.9.2.1 Every ungrounded supply conductor from a storage battery shall have a manually reset, trip-free circuit breaker or fuse, unless the supply conductor is in the main power feed circuit from the battery to an engine cranking motor.
8.9.2.2 The circuit breaker or fuse, as specified in paragraph 8.9.2.1 shall be within 1800 mm (5 ft 11 in) of the battery, as measured along the conductor, unless the circuit has a switch that disconnects the battery.
8.10.1 The front side of panelboards (i.e., switch and breaker operating face) shall be readily accessible, and the rear side (i.e., terminal and connection side) shall be accessible.
8.10.2 Panel boards shall be designed, constructed, and installed so that there are no exposed live parts accessible to the operator in the normal operating position.
8.10.3 Panel boards shall be weatherproof or protected from weather and splash.
8.10.4 Vessels equipped with both AC and DC electrical systems shall have their distribution from separate panel boards. If both systems share a common enclosure, it must have a partition or have other positive means provided to clearly separate the AC and DC sections from each other. Wiring diagrams to identify circuits, components, and conductors shall be included.
8.10.4.1 The switchboard or panel board shall be provided with clear permanent markings of the nominal voltage and types and provide circuit identification.
8.11.1.1 This section applies in respect of non-pleasure craft only.
8.11.2 Emergency Lighting for Non-Pleasure Craft Only
8.11.2.1 A system of emergency lighting shall be provided, to allow the passengers and crew to exit from any area of the vessel. The lighting units shall be of a self-contained type, rechargeable from the vessel's electrical distribution system, and fitted with a charge indicator. As an alternative to an emergency hard-wired lighting system, rechargeable or non-rechargeable portable hand lanterns of not less than the 6-V battery type may be provided. For those vessels with non-rechargeable lanterns, a spare battery shall be carried and batteries shall be replaced with new batteries annually.
8.11.3.1 All cables shall have stranded copper conductors and a protective covering of either watertight metallic sheath or impervious non-metallic sheath that is compatible with the insulation and shall be rated for at least 75°C service. The cables shall be installed and terminated in accordance with subsections 8.7.4 and 8.7.5.
8.11.3.2 All connections shall be made in terminal or junction boxes providing mechanical and environmental protection.
8.12.1.1 This subsection applies to pleasure craft only.
8.12.1.2 This subsection does not apply to:
8.12.2.1 Every permanently installed conductor in a circuit which has a nominal voltage of 50 V or more shall be not less than the nominal voltage of the system and shall:
8.12.2.2 Where the nominal circuit voltage of each of three or more current carrying conductors in a duct, bundle, or cable is 50 V or more, the amperages of each of those conductors shall not exceed that listed in Table 8-2 multiplied by the correction factor in Note 2 of Table 8-2 for the applicable number of conductors.
8.12.2.3 The installation of the electrical equipment in systems of 50 V or over shall conform to Transport Canada Marine Electrical Standards, TP127, Part 1 or ABYC Standard for Small Vessels Chapter 8.
8.13.1 Permanently installed electrical systems of 50 V or over shall conform to Transport Canada Marine Electrical Standards, TP127, Part 1, or ABYC Standards for Small Craft, Chapter 8.
8.13.2 All connections shall be made in terminal or junction boxes, which shall provide mechanical and environmental protection.