Every fishing vessel 15 g.r.t. or greater shall be provided with fire extinguishers as set out in Table I, or with equivalent extinguishers as shown in Table II.
TABLE I
|
|
Length of Vessel |
Fire Extinguishers |
|---|---|---|
|
1. |
Not exceeding 12.2 m if construction of closed type |
4.5 L foam |
|
2. |
Exceeding 12.5 m but not exceeding 19.8 |
one 9 L foam and one 4.5 L foam |
|
3. |
Exceeding 19.8 m but not exceeding 24.4m |
two 9 L foam |
TABLE II
|
Item |
Foam (Litres) |
CO2 (Kilograms) |
Dry Chemical (Kilograms) |
|---|---|---|---|
|
1. |
4.5 |
2.25 |
1 |
|
2. |
9 |
4.5 |
2.55 |
A fishing vessel that is equipped with a cooking or heating appliance shall be fitted with an additional 4.5 L foam fire extinguisher or equivalent.
Every fishing vessel 15 g.r.t. or greater must also carry fire buckets in accordance with the following:
|
Length of Vessel |
Number of Buckets |
|---|---|
|
Not exceeding 12.2 m if construction of open type |
one |
|
Not exceeding 12.2 m if construction of closed type |
two |
|
Exceeding 12.2 m but not exceeding 19.8 m |
three |
|
Exceeding 19.8 m but not exceeding 24.4 m |
four |
Every fishing vessel of open construction not exceeding 15 g.r.t. shall carry a fire bucket; if construction is closed, it shall carry, in addition to the fire bucket, one 4.5 L foam fire extinguisher or equivalent. If equipped with a cooking or heating appliance, the vessel shall carry an additional 4.5 L fire extinguisher.
In addition, every fishing vessel 15 g.r.t. or greater and exceeding 12.2 m in length shall be equipped with a hand-operated or engine-driven fire pump with a hose and nozzle.